DOWNLOAD

Product Documents & Test Reports

Measured by accredited labs · Original reports downloadable · Print-friendly specifications

TEST REPORTS

Third-Party Test Reports · Original Downloads

All four reports come from CNAS-accredited laboratories with verifiable report numbers.

Optical & Thermal

Shading Coefficient Test Report

No. WT2025E09B00609

Shading coefficient SC 0.14
Direct solar reflectance 75.2%
Visible light transmittance 28%
Per GB/T 2680-2021

Download Report (PDF)
China Building Material Test Certification Group CTC · National Center for Safety Glass & Quartz Glass Quality Inspection · CNAS L0690
Thermal Insulation

Thermal Transmittance Test Report

No. BETC-T5CC-2025-00044

Deployed K=1.9 W/(㎡·K)
Retracted K=2.3 W/(㎡·K)
(K-value = thermal transmittance — lower is better)
Per GB/T 8484-2020
Full-size specimen test (1500×1500 mm)

Download Report (PDF)
CABR Testing Center · National Center for Quality Inspection & Test of Building Engineering · CNAS L0230
Fire Safety

Fire Performance Test Report

No. BETC-T4BC-2025-00042

Fire performance B1 (B-s1, d0)
Per GB/T 20284-2006
GB/T 8626-2007
Classified per GB 8624-2012

Download Report (PDF)
CABR Testing Center · National Center for Quality Inspection & Test of Building Engineering · CNAS L0230
Healthy & Eco

Formaldehyde Content Test Report

No. BETC-T6AC-2025-00515

Formaldehyde compliant with JG/T 254-2015
Table 2, JG/T 254-2015
Per GB/T 2912.1-2009
Water extraction method

Download Report (PDF)
CABR Testing Center · National Center for Quality Inspection & Test of Building Engineering · CNAS L0230

Metric Definitions (to avoid misreading)

  • Total solar reflectance 88% —— Total solar reflectance — the product technical metric, covering reflection across the full visible-to-near-infrared band;
  • Direct solar reflectance 75.2% —— GB/T 2680-2021 National-standard measured value. Different metric family from total solar reflectance — different numbers are expected;
  • Shading coefficient SC 0.14 —— Calculated per JGJ/T 151-2008 — equivalent to cutting about 86% of solar heat gain;
  • Near-infrared reflectance 96.5% —— Near-infrared band metric — 52% of solar heat comes from NIR;
  • Visible light transmittance 28% —— Laboratory-measured per national standard on samples — indicates how much daylight is retained indoors with the curtain deployed.
SPEC SHEETS

Series Specifications · Print-friendly

Click “Print / Save as PDF” to export a series specification sheet

Huineng ESEC 2.5 range

Insulation flagship · Reflects solar heat · First choice for west-sun curtain wall retrofits
Total solar reflectance 88%
Membrane typeInsulating view-through energy-saving window curtain (grey)
Total solar reflectance88%(product technical metric)
Infrared reflectance97%
UV blocking rate>99%
Visible light transmittance (VLT)10%
Anti-glare & privacyGood
Best forWest-sun curtain wall insulation retrofits
Shading CoefficientSC 0.14 (per JGJ/T 151-2008, report:WT2025E09B00609)
Heat-transfer coefficient K (adjustable)Deployed K=1.9, retracted K=2.3 W/(㎡·K) — lower is better (BETC-T5CC-2025-00044)
Fire PerformanceClass B1 (B-s1, d0), GB 8624-2012 (BETC-T4BC-2025-00042)
EnvironmentalFormaldehyde compliant with JG/T 254-2015 (BETC-T6AC-2025-00515)
InstallationInstalled on the interior side — no removal of existing glazing, no damage to the curtain wall; most spaces finished in one day

Huilang ESEC 10 range

Strong shading + anti-glare + privacy · Daytime privacy built-in
Total solar reflectance 87%
Membrane typeInsulating view-through energy-saving window curtain (grey)
Total solar reflectance87%(product technical metric)
Infrared reflectance95%
UV blocking rate>99%
Visible light transmittance (VLT)3%
Anti-glare & privacyExcellent — privacy by day, built in
Best forGlare & privacy driven scenes (meeting rooms / offices / street-facing facades)
Heat-transfer coefficient K (adjustable)Deployed K=1.9, retracted K=2.3 W/(㎡·K) — lower is better (BETC-T5CC-2025-00044)
Fire PerformanceClass B1 (B-s1, d0), GB 8624-2012 (BETC-T4BC-2025-00042)
EnvironmentalFormaldehyde compliant with JG/T 254-2015 (BETC-T6AC-2025-00515)
InstallationInstalled on the interior side — no removal of existing glazing, no damage to the curtain wall; most spaces finished in one day

Huiyuan ESEC 100 range

Radiative cooling · Vents absorbed heat away · For cutting-edge energy projects
Radiative cooling film (blue)
Membrane typeRadiative cooling film (blue)
Infrared reflectance50.4%(plus 8-13μm atmospheric-window radiative heat dissipation)
UV blocking rate99.7%
Visible light transmittance (VLT)5%
Anti-glare & privacyGood
Best forProjects pursuing cutting-edge energy-saving technology
Heat-transfer coefficient K (adjustable)Deployed K=1.9, retracted K=2.3 W/(㎡·K) — lower is better (BETC-T5CC-2025-00044)
Fire PerformanceClass B1 (B-s1, d0), GB 8624-2012 (BETC-T4BC-2025-00042)
EnvironmentalFormaldehyde compliant with JG/T 254-2015 (BETC-T6AC-2025-00515)
InstallationInstalled on the interior side — no removal of existing glazing, no damage to the curtain wall; most spaces finished in one day

Need an energy calculation for your building?

Free on-site measurement — annual kWh savings, cost savings and payback report powered by our calculation model

Talk to an Engineer →